Information on Small Appliance Practice Test 2
This is the second free practice test of three in our Type 1 series for handling small-appliance refrigerants and servicing small-appliance equipment. Our practice tests are mobile-friendly tests and render great on phones and tablets for students and apprentices on the go. Please consider sharing with others that may find them useful, individually or in forums. Thanks… NT.
* NOTE: Having a pressure-temperature reference for commonly used refrigerants is required to answer some of the questions on our practice tests unless you have an amazing memory.
- This practice test is free. Take it as often as you like.
- Contains 25 questions.
- Pressing the submit button immediately returns your resulting score.
- Passing score is 70%.
- Correct answer information is provided for questions answered incorrectly.
- Good luck!
Trade Category: | HVACR |
Test Category: | EPA 608 Certification |
Test Subject: | Type 1 – Small Appliance |
Test Number: | 2 of 3 |
Questions on Test: | 25 |
Passing Score: | 70% |
#1. When using a passive system-dependent recovery method on an appliance with an operating compressor, you should run that appliances compressor
Correct answer is C: for several minutes, shutting it off, then recover the refrigerant from the low side.
When using a passive system-dependent recovery method on an appliance with an operating compressor, you should run that appliances compressor for several minutes, shutting it off, then recover the refrigerant from the low side.
#2. A passive system-dependent recovery device for small appliances
Correct answer is C: captures refrigerant in a non-pressurized container.
A passive system-dependent recovery device for small appliances captures refrigerant in a non-pressurized container.
#3. The sale of CFC and HCFC refrigerants is
Correct answer is D: restricted to technicians who are EPA certified in refrigerant recovery.
The sale of CFC and HCFC refrigerants is restricted to technicians who are EPA certified in refrigerant recovery.
#4. Which of the refrigerants listed below should be recovered with current EPA-approved recovery devices?
Correct answer is D: None of the above
#5. When servicing a small appliance with a leak
Correct answer is C: it is not mandatory to repair the leak but doing so is most responsible.
When servicing a small appliance with a leak it is not mandatory to repair the leak but doing so is most responsible.
#6. For which of the following refrigeration systems/appliances would it be permissible to use a passive recovery device for refrigerant recovery?
Correct answer is D: A domestic refrigerator.
For which of the following refrigeration systems/appliances would it be permissible to use a passive recovery device for refrigerant recovery? A domestic refrigerator.
#7. When using any equipment or servicing any system that has schrader valves, it is critical to
Correct answer is D: All of the above.
When using any equipment or servicing any system that has schrader valves, it is critical to be vigilant of the following:
- Inspect the schrader valve core for bends and breakage.
- Replace any damaged schrader valve cores to prevent leakage.
- Cap the schrader ports to prevent accidental depression of the valve core.
#8. If R-12 or R-22 are exposed to high temperatures from open flames, glowing hot metal surfaces etc, these refrigerants can decompose to form
Correct answer is A: hydrochloric and hydrofluoric acids.
If R-12 or R-22 are exposed to high temperatures from open flames, glowing hot metal surfaces etc, these refrigerants can decompose to form hydrochloric and hydrofluoric acids.
#9. When using a graduated charging cylinder, any refrigerant that is vented from the charging cylinder
Correct answer is B: must be recovered.
When using a graduated charging cylinder, any refrigerant that is vented from the charging cylinder must be recovered.
#10. A standard vacuum pump designed specifically for evacuation and dehydration can
Correct answer is B: never be used as a recovery device in combination with a pressurized container.
A standard vacuum pump designed specifically for evacuation and dehydration can never be used as a recovery device in combination with a pressurized container.
#11. The EPA section 608 certification must be renewed every
Correct answer is D: The EPA certification has no expiration date.
The EPA Section 608 Stationary Refrigeration certification does not have to be renewed. The EPA certification has no expiration date.
#12. Prior to shipping any used refrigerant it is necessary to
Correct answer is D: All of the above.
Prior to shipping any used refrigerant it is necessary to make sure of the following:
- Properly label the refrigerant container.
- Properly complete shipping paperwork.
- Check that the refrigerant container meets Department of Transportation standards.
#13. A refrigerant that can be used as a direct service “drop-in” substitute for R-12 in a small appliance is
Correct answer is D: None of the above.
There is no “drop-in” replacement for R-12. Although R-134a is considered a preferred replacement refrigerant, it is not a “drop-in” which is a term that implies that you do not have to change compressor lubricant, expansion valve etc.
#14. After installing and opening a piercing access valve, if the system is _______ do not begin the recovery procedure.
Correct answer is A: 0 psig
After installing and opening a piercing access valve, if the system is 0 psig do not begin the recovery procedure.
#15. The EPA definition of a small appliance includes which of the following?
Correct answer is D: Both A and B
The EPA definition of a small appliance includes the following:
- A device manufactured, charged, and hermetically sealed from the factory.
- A device with a charge of 5 pounds or less.
#16. When using _________ , it is essential to take extra measures such as heating or striking the compressor, to help release trapped refrigerant from the compressor oil.
Correct answer is C: a passive system-dependent recovery device on a small appliance with a non-operating compressor
When using a passive system-dependent recovery device on a small appliance with a non-operating compressor, it is essential to take extra measures such as heating or striking the compressor, to help release trapped refrigerant from the compressor oil.
#17. It is an EPA regulation that any person who opens an appliance for maintenance, service, or repair, must have at least one self-contained recovery machine available at their place of business. The only exception to this rule are persons working on
Correct answer is A: small appliances.
It is an EPA regulation that any person who opens an appliance for maintenance, service, or repair, must have at least one self-contained recovery machine available at their place of business. The only exception to this rule are persons working on small appliances.
#18. Which of the following are part of the EPA’s recommended safe work practices?
Correct answer is D: Both A and C.
The following are part of the EPA’s recommended safe work practices:
- Wear safety glasses or goggles when working with any compressed gas.
- Wear butyl-lined gloves when connecting/disconnecting hoses.
#19. Recovery devices that were manufactured before November 15 1993 and are used for recovery of refrigerant from small appliances must be capable of
Correct answer is A: recovering 80% of the refrigerant whether or not the compressor is operating or achieving a 4-inch vacuum under conditions of ARI 740-1993.
Recovery devices that were manufactured before November 15 1993 and are used for recovery of refrigerant from small appliances must be capable of recovering 80% of the refrigerant whether or not the compressor is operating or achieving a 4-inch vacuum under conditions of ARI 740-1993.
#20. Piercing-type valves should only be used on which of the following type tubing materials?
Correct answer is D: Both A and B
You’re going to have a hard time even trying to pierce a steel line… lol
#21. When using a passive system-dependent recovery process, you should access both the high side and low side of the system for the refrigerant recovery if
Correct answer is D: the systems compressor does not run.
When using a passive system-dependent recovery process, you should access both the high side and low side of the system for the refrigerant recovery if the systems compressor does not run.
#22. On a small appliance with an operating compressor that has a completely plugged capillary tube, what is the minimum number of access valves that are needed to evacuate the refrigerant?
Correct answer is B: Only one access valve on the high side of the system.
On a small appliance with an operating compressor that has a completely plugged capillary tube, what is the minimum number of access valves that are needed to evacuate the refrigerant? Only one access valve on the high side of the system.
#23. Technicians with a Type I small appliance certification are certified to recover refrigerant during the maintenance, service, or repair of
Correct answer is B: packaged terminal air-conditioners (PTACs) with pounds or less of refrigerant.
Technicians with a Type I small appliance certification are certified to recover refrigerant during the maintenance, service, or repair of packaged terminal air-conditioners (PTACs) with pounds or less of refrigerant.
#24. A recovery cylinder which is half full of recovered R-500 at normal room temperature, about 75F, in the absence of non-condensables, will be pressurized to
Correct answer is C: 95 psig
A recovery cylinder which is half full of recovered R-500 at normal room temperature, about 75F, in the absence of non-condensables, will be pressurized to 95 psig.
#25. A refrigerant that can be used as a direct service “drop-in” substitue for R-22 in a small appliance is
Correct answer is D: None of the above
Again, the phrase “drop-in” implies exactly that. But you cant just do that without changing compressor lubricant, expansion valves etc.
More Type 1 Small Appliance Practice Tests
Type 1 Test 1
Type 1 Test 2
Type 1 Test 3